Door Switch Check

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Remove right side panel.

3. Open and close the steamer’s door while looking to see that the door switch actuator rod actuates the door

switch when the rod moves.

4. Disconnect the wiring harness from the switch terminals at the two places shown above (where the test-probe

tips are located).

5. Place the test probes on the switch terminals (as shown above).

6. Check for continuity with the door open (there should NOT be continuity).

7. Check for continuity when the door is closed (there should be continuity).

8. If the continuity checks are not correct, replace the door switch.

9. Reconnect the wiring harness to the switch terminals.