NCB Return Codes

80

8.1

Network Control Block (NCB) Return Codes

The bridge returns the following codes into the NCB_RETCODE field. Note that

some application programs such as Modsoft may not map these codes to the

correct error message.

ERR_success 0

/* NCB command completed normally */

ERR_bad_buffer_length 1

/* Bad send or status buffer size */

ERR_invalid 3

/* invalid NetBIOS command */

ERR_timeout 5

/* Command time-out has expired */

ERR_buffer_too_small 6

/* Receive buffer not big enough */

ERR_bad_session_num 8

/* Bad value in NCB_LSN */

ERR_no_RAM 9

/* LAN card doesn’t have enough memory*/

ERR_session_closed 0xa

/* This session is closed */

ERR_cancel 0xb

/* Command has been closed */

ERR_dup_local_name 0xd

/* Name already exists for this PC */

ERR_name_table_full 0xe

/* Local name table is full */

ERR_active_session 0xf

/* Can’t delete name - used in session*/

ERR_sess_table_full 0x11

/* Local session table is full */

ERR_no_listen 0x12

/* Remote PC not listening for call */

ERR_bad_name_num 0x13

/* Bad value in NCB_NUM field */

ERR_no_answer 0x14

/* No answer to CALL or no such remote*/

ERR_no_local_name 0x15

/* No such name in local name table */

ERR_duplicate_name 0x16

/* Name is in use elsewhere on net */

ERR_bad_delete 0x17

/* Name incorrectly deleted */

ERR_abnormal_end 0x18

/* Session aborted abnormally */

ERR_name_error 0x19

/* 2 or more identical names in use! */

ERR_bad_packet 0x1a

/* Bad NetBIOS packet on network */

ERR_card_busy 0x21

/* network card is busy */

ERR_too_many_cmds 0x22

/* Too many NCB commands queued */

ERR_bad_card_num 0x23

/* bad NCB_LANA_NUM - must be 0 */

ERR_cancel_done 0x24

/* command finished while cancelling */

ERR_no_cancel 0x26

/* Command can’t be cancelled */

ERR_busy 0xff