Configuring the Bridge

28

3.2

Overview: Software Configuration

Here is an overview of the tasks for configuring the bridge. The references are to

the sections of this guidebook that show the detailed installation steps.

3.2.1

Setting the Ethernet Configuration

Configure the bridge’s IP address and other Ethernet parameters to allow your

host application to recognize the bridge.

Configuration With a BOOTP Server (Section 3.3)

If a BOOTP server exists, configure the server to recognize the bridge. When the

bridge is initially powered up, it will attempt for 30 seconds to connect to a BOOTP

server. If the server is found, the bridge will automatically configure for the

Ethernet connection. Note that you will still have to set up the mappings between

Ethernet and Modbus Plus devices, or you can create a host file for centralized

mapping which you can download.

Configuration With the CFGUTIL Utility (Section 3.4)

If a BOOTP server is not available, you can use the internal CFGUTIL program to

configure the bridge. Connect a keyboard and VGA monitor to the bridge, start the

utility, and use it to setup the bridge’s IP and gateway addresses, and subnetwork

mask.

3.2.2

Setting the Modbus Plus and TCP/IP Address Mapping

Setup your bridge’s mapping tables to control the flow of traffic through the bridge.

Your mappings define the routing destinations for messages received by the

bridge on one network and passed through it to destinations on the other network.

Setting the Mapping: TCP/IP to Modbus Plus (Sections 3.5 and 3.6)

Messages received by the bridge over TCP/IP contain a Destination Index

address byte in the range 1 ... 249 decimal. This byte corresponds to the
dest_idx

field in Modbus Application Protocol commands issued in Modicon

panel software such as Concept and Modsoft. The bridge maps this byte to one of

249 possible Modbus Plus node destinations. You define the Modbus Plus node

address to be associated with each Destination Index byte value.

Setting the Mapping: Modbus Plus to TCP/IP (Sections 3.7 and 3.8)

Messages received by the bridge over Modbus Plus contain a routing byte in the

range 1 ... 255 decimal (the dest_idx field). The bridge maps this byte to one of

255 IP destinations. You define the IP address to be associated with each

Modbus Plus routing byte value.