7

Table 6 Environmental

Parameter

Reference

Limits

Temperature, Storage

IEC 68--2--1

IEC 68--2--2

--25_ C for 96 hrs

+70_ C for 96 hrs

Temperature, Operating

IEC 68--2--14

0...50_ C ambient

Humidity, Non--operating

IEC 68--2--3

95% RH at 50_ C for 24 hrs

non--condensing

Humidity, Operating

IEC 68--2--3

95% RH at 50_ C for 24 hrs

non--condensing

Vibration, Operating

IEC 68--2--6

Sinusoidal, 10 sweeps

10...57 Hz: 0.075 mm amplitude

57...150 Hz: 1 g

Shock, Operating

IEC 68--2--27

3 shocks/axis

15 g half sine, 11 ms

Free Fall, Packaged

IEC 68--2--32

1 drop at 1.220 m

5 drops at 0.610 m

Free Fall, Unpackaged

IEC 68--2--32

2 drops at 0.500 m

Table 7 Packaging

Parameter

Desription

Enclosure Material

Steel, baked enamel

Weight, Product

9.4 lb (4.3 kg)

Weight, Shipping

10.5 lb (4.8 kg)

Table 8 Agency Approval

Agency

Status

UL, CSA

Approved

CE

Meets CE Requirements (see Section 2.6)