Interface specifications, Rs-232c, Rs-485 – Sanyo DSR - 300 User Manual
Page 82

English
81
(when optional interface board is installed)
1
INTERFACE SPECIFICATIONS
Data format
Only the data transfer speed can be set. (JP. 69)
Communication protocol
Communication is carried out in units of 1 byte. After the
PC has transmitted a single byte, it waits for a response
from the unit before sending the next byte.
An ON (F6) command is sent as the start command, and
the unit will continue to accept commands until an OFF
(F7) command is sent as the end command. Whenever the
unit receives a command, it returns an ACK (OA).
When using RJ-11 connector
A: Non-inverting driver output, non-inverting receiver input
B: Inverting driver output, inverting receiver input
Communication wire: 2-core wire
Communication system: Half duplex
Data format
To set the data transmission speed, address and
termination switch, see “Settings for RS-232C and RS-
485” (JP. 69).
Communication protocol
A proprietary Sanyo protocol (SSP: Security Serial
Protocol) is used. Use of a Sanyo system controller is
recommended.
RS-232C
Pin No.
Signal
Operation
Signal direction
1
–
–
–
2
RXD
Reception
PC
→ Unit
3
TXD
Transmission
Unit
→ PC
4
–
–
–
5
GND
Ground
–
6
–
–
–
7
RTS
Transmission
request
Unit
→ PC
8
–
–
–
9
–
–
–
Mode
Asynchronous
Character length
8 bits
Data transmission
speed
2400, 4800, 9600, 19200 bps
Parity check
None
Stop bit
1
9
8
7
6
5
4
3
2
1
RS-485
Pin No.
Connector A signal
Connector B signal
1
Not used
Not used
2
Not used
Not used
3
A
B
4
B
A
5
Not used
Not used
6
Not used
Not used
Mode
Asynchronous
Character length
8 bits
Data transmission
speed
2400, 4800, 9600, 19200 bps
Parity check
None
Start bit
1
Stop bit
1
1
6