Sony KL-W9000 User Manual

Page 32

background image

– 32 –

KL-W7000/W9000

RM-Y980

Adjustment Items and Procedure

Tools and

Test Points

Adjustment Places Illustration Waveforms and Values

Signals

* TP5611 [BLBS]
* TP5607 is Ref.

GND

* TP5603 [B-SIG2]

* TP5603 [B-SIG2]

* TP 5602 [B-SIG1]
* TP5604 [B-SIG3]
* TP5603 [B-SIG2]

3)

B channel
1. Using *DC power, apply 0V to *TP5611.

2. Connect *oscilloscope to *TP5603, and adjust *RV5605 so

that 10 IRE ~ 100 IRE (A) becomes *1.35

±

0.02Vp-p.

3. Adjust *RV5601 so that the forward 10 IRE ~ reverse 10 IRE

(B) becomes *5.90

±

0.02Vp-p at *TP5603.

4. Confirm that a difference in voltage amplitude of forward 10

IRE ~ 100 IRE and forward 10 IRE ~ reverse 10 IRE between
waveform at *TP5602,*TP5604 and waveform at *TP5603 is
within

±

150mV.

4.

Vcom Adjustment

*Using *I

2

C bus encoder, set the NT-WIDE mode.

*Enter NT double speed 10-step signal of *bias 2.2V and amplitude
1.8Vp-p to the CN5201 pins 2~4.

*I

2

C bus encoder

*

* DC power

* Oscilloscope

* RV5605 [B. GAIN]

* RV5601 [B. BIAS]

* A : 1.35

±

0.02Vp-p

* B : 5.90

±

0.02Vp-p

* TP5203 [Rch OUT]

* TP5205 [R-Vcom

OUT]

* TP5403 [Gch OUT]

*

(Value in 1) – 0.60

±

0.02V

* RV5202 [R.VCOM]

1. Measure voltage at the *TP5203 with digital voltmeter.

2. Adjust *RV5202 so that the voltage at *TP5205 becomes

*(Value in 1) – 0.60

±

0.02V.

3. Measure voltage at the *TP5403 with digital voltmeter.

* Voltmeter

* Voltmeter

Use TP5201,
TP5401 and TP5601
as reference GND
respectively.

10

GND

IRE

100 IRE

$
4

2.0

±

0.02 Vp-p

2.7

±

0.02 V

10

A

B

100 IRE

IRE

10 IRE