– 30 –

KL-W7000/W9000

RM-Y980

Adjustment Items and Procedure

Tools and

Test Points

Adjustment Places Illustration Waveforms and Values

Signals

* L5002

* L5004

* 13.67

±

0.10MHz

*

* 10.22

±

0.05MHz

*

* NTSC signal

* Frequency counter
* Double speed NTSC
* Oscilloscope

* NTSC signal

* Frequency counter

* Double speed NTSC
* Oscilloscope

C Board Adjustment

1.

PLL fo adjustment
1)

WIDE mode
1. Select WIDE mode.
2. Open the CN5202 pin 1, H.SYNC input.
3. Connect *IC5004 pin 2 to the GND (*TP5009) via 100

resis-

tance.

4. Connect *frequency counter to the pin 1 of *IC5004.
5. Adjust *L5002 so as to satisfy the *specified value.
6. Input H.SYNC for NT double speed, and confirm the wave-

form at the *TP with *oscilloscope.

2)

NORMAL mode
1. Select NORMAL mode.
2. Open the CN5202 pin 1, H.SYNC input.
3. Connect *IC5004 pin 2 to the GND (*TP5009) via 100

resis-

tance.

4. Connect *frequency counter to the pin 1 of *IC5004.
5. Adjust *L5004 so as to satisfy the *specified value.
6. Input H.SYNC for NT double speed
7. Confirm the waveform at the *TP5004 with *oscilloscope.

* IC5004 pin 2
* TP5009 Jig land
* IC5004

* TP5007 (RPD2)

* IC5004 pin 2
* IC5009
* IC5004 pin 1

* TP5007 (RPD1)

31.78

µ

s

2.39

±

0.1

µ

s

5.0Vp-p

Use TP5009 as
reference GND.

Use TP5009 as
reference GND.

2.3

±

0.3 V