OP (Others)

Item

Register Name

Range

Standard Values

Typical Standard Values

Display
0 OSDH

Display H Position

0-63

10 (VIDEO)

7(RGB)

2 Kinds (VIDEO, RGB)

1 OSDV

Display V Position

0-63

7 (VIDEO)

7(RGB)

2 Kinds (VIDEO, RGB)

2 ASHT

Auto Shut Off

0,1

Not used

0: OFF, 1: ON

3 CPWR

CH Power ON

Not used

Not used

4 AGCH

AGC Voltage High

0-15

Not used

Not used

5 AGCL

AGC Voltage Low

0-15

Not used

Not used

6 DBSS

DBS Category Yes/No

Not used

Not used

7 EDCK

EDTV FULL Mode Detection

0,1

Not used

Not used

8 AION

AI AUTO

0,1

Not used

Not used

9 K

Picture Adjusting Variable K

0-7

1

Don't set “0” (Actual value is
1/8~7/8)

10 L

Picture Adjusting Variable L

0-7

0

0~7 is converted into 1~8 in actual use.

11 LENS

Display only

0

Lens focus adj.

12 PANEL 0:Green, 1:Red, 2:Blue, 3:White

0-3

Panel position adj.

13 WHITE APL

0-1

White balance adj. (0: GAIN, 1: BIAS)

14 WIND

Display only

0

Window signal

15 STEP

Display only

0

00: Normal, 01: Pattern 1,
02: Pattern 2

16 EDFL

EDTV FULL Detection ON

0,1

Not used

Not used

17 BC

g_bs_search [0]

1-15

Not used

Not used

18 TIME

Lamp Counting Timer

Current time count and 0 time are
displayed alternately with UP/DOWN

19 FMTL

fh of distinction difference range

0

±

((3+FHTL)

×

0.2) kHz

20 FVTL

fv of distinction difference range

0

±

(1.0+FVTL) Hz

21HV1

Threshold of scanning line

0-15

(505+ (5

×

HV1)) lines

distinction (low)

22 HV2

Threshold of scanning line

0-15

(555+ (5

×

HV2)) lines

distinction (high)

23 MINH

fh of the frequency correspond

0-31

20+ ((3+FHTL)

×

0.2) kHz

to MIN

24 MAXH

fh of the frequency correspond

0-31

42+ ((3+FHTL)

×

0.2) kHz

to MAX

25 MINV

fv of the frequency correspond

0-15

(42+MINV) Hz

to MIN

26 MAXV

fv of the frequency correspond

0-15

(77+MAXV) Hz

to MAX

27 FHAG

Equivalence frequency of fh

0-15

FHAG (20

×

FHAGms)

changed detection

28 FVAG

Equivalence frequency of fv

0-15

FHAG (20

×

FVAGms)

changed detection

29 NSAG

Equivalence frequency of

0-15

Not used

non-signal detection (on signal)

30 FHMJ

fh difference range of before

0-7

±

((1+FHMJ)

×

0.2) kHz

the signal distinction

31 FVMJ

fv difference range of before

0-7

±

((3+FVMJ)

the signal distinction

TP (Model Discrimination)

Item Display

Register Name

Range

Standard Values

Typical Standard Values

0 WIDE

HH

0,1

Not used

1 TIME

TIMER

0,1

0,1

Fan stop time switching
0: 10 min (normal), 1: 10 sec

2 KL37

KL-W7000 model

0,1

0,1

0: KL-W9000 1: KL-W7000