beautypg.com

Locating the new water heater – State Industries GS675YRVIT User Manual

Page 9

background image

9

facts to consIder aBout the locatIon

Carefully choose an indoor location for the new water heater, because

the placement is a very important consideration for the safety of the

occupants in the building and for the most economical use of the

appliance.

this water heater is not for use in manufactured

(mobile) homes or outdoor installation.

Whether replacing an old water heater or putting the water heater in

a new location, the following critical points must be observed:

1. Select a location indoors as close as practical to the vent terminal or

location to which the water heater vent piping is going to be connected,

and as centralized with the water piping system as possible.

2. Selected location must provide adequate clearances for servicing

and proper operation of the water heater.

Installation of the water heater must be accomplished in such a manner

that if the tank or any connections should leak, the flow will not cause

damage to the structure. For this reason, it is not advisable to install

the water heater in an attic or upper floor. When such locations cannot

be avoided, a suitable metal drain pan should be installed under the

water heater. Drain pans are available at your local hardware store.

Such a drain pan must have a clearance of at least 1.0” (2.5cm)

greater than any point on the water heater’s outer jacket and must

be piped to an adequate drain. The pan must not restrict combustion

air flow. For example, if a circular pan is used, it must be a minimum

of 27” (69cm) in diameter, see Figure 1.

Water heater life depends upon water quality, water pressure and

the environment in which the water heater is installed. Water heaters are

sometimes installed in locations where leakage may result in property

damage, even with the use of a drain pan piped to a drain. However,

unanticipated damage can be reduced or prevented by a leak detector or

water shut-off device used in conjunction with a piped drain pan. These

devices are available from some plumbing supply wholesalers and

retailers, and detect and react to leakage in various ways:

• Sensors mounted in the drain pan that trigger an alarm or turn off the

incoming water to the water heater when leakage is detected.

• Sensors mounted in the drain pan that turn off the water supply to

the entire home when water is detected in the drain pan.

• Water supply shut-off devices that activate based on the water

pressure differential between the cold water and hot water pipes

connected to the water heater.

• Devices that will turn off the gas supply to a gas water heater while

at the same time shutting off its water supply.

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS

(VAPORS) ARE LIKELY TO BE PRESENT OR STORED

(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable

liquids (such as gasoline, solvents, propane (LP or butane, etc.) and

other substances (such as adhesives, etc.) emit flammable vapors

which can be ignited by a gas water heater’s hot surface igniter or

main burner. The resulting flashback and fire can cause death or

serious burns to anyone in the area.

Also, the water heater must be located and/or protected so it is not

subject to physical damage by a moving vehicle.

locatInG the new water heater

This water heater must not be installed directly on carpeting. Carpeting

must be protected by metal or wood panel beneath appliance extending

beyond full width and depth of appliance by at least 3” (7.6 cm) in any direction,

or if appliance is installed in an alcove or closet, entire floor must be covered

by the panel. Failure to heed this warning may result in a fire hazard.

This manual is related to the following products: