Appendix H- Mounting the SonicWALL PRO 200 and PRO 300
The SonicWALL PRO 200 and SonicWALL PRO 300 are designed to be mounted in a standard 19-
inch rack mount cabinet. The following conditions are required for proper installation:
•
Use the mounting hardware recommended by the rack manufacturer and ensure that the rack
is adequate for the application.
•
Four mounting screws, compatible with the rack design, must be used and hand tightened to
ensure secure installation. Choose a mounting location where all four mounting holes line up
with those of the mounting bars of the 19-inch rack mount cabinet.
•
Mount in a location away from direct sunlight and sources of heat. A maximum ambient temper-
ature of 104º F (40º C) is recommended.
•
Route cables away from power lines, fluorescent lighting fixtures, and sources of noise such as
radios, transmitters, and broadband amplifiers
•
Ensure that no water or excessive moisture can enter the unit.
•
Allow unrestricted airflow around the unit and through the vents on the side of the unit. A mini-
mum of 1 inch (25.44mm) clearance is recommended.