TROUBLESHOOTING

Continued From

Previous Page

Go to the motor and remove the wire terminal cover.

Check that the red wire is capped off.

Remove the wire nuts from the black and white wires.

Check that the wires are twisted together securely.

Check that the common wire is connected to the motor

black wire.

Place a DVM on the black and the white wire.

Check that the neutral wire is connected to the white wire.

Connect the main power supply.

Turn on the blower switch.

Yes

No

Check all wiring for loose

terminals or breaks.

Check Power Switch

and Door Switch per

the instructions.

Remove the wire nuts

from the red, white, and

black wires.

Replace the motor if

different.

Connect the main power

supply.

Check for approx. 1.9

ohms across the white

and black wire, then the

white and red.

Test oven.

Disconnect the main

power supply.

Power?

Place a DVM on the door

switch terminals with the

connected wires.

Press the switch actuator

lever.

Close the oven door.

Yes

No

Replace the switch.

Test oven.

Yes

No

Continuity?

Loosen the 2 screws on

the door switch bracket

and adjust it to the door

hinge to actuate the switch.

Reinstall the kick panel.

Connect the main power

supply.

Test oven.

Continuity?

CAUTION!

Be sure the main power is

disconnected.