background image

A

DJUSTMENTS

M

ODEL

400 R

ESTAURANT

R

ANGES

P

AGE

30

OF

64

O

PERATOR

S

M

ANUAL

1182299

REV

3 (05/05) D

RAFT

ADJUSTMENTS

The temperature is stable when the

change is no more than 5

°

F.

Reinstall the silver cover in

the knob center.

The temperature should be within

+/- 10

°

F of the setting.

To calibrate the temperature go to

the center of the thermostat.

Scrape the paint seal off of the

screw.

NOTE! Only turn this screw by

small increments.

While holding the knob at the

400

°

F setting, push the screw in,

and turn it in the direction indicated

to calibrate the temperature.

If the temperature cannot be set to

within +/-10

°

F replace the

thermostat and retest.

Repeat this procedure until the

temperature stabilizes to +/-10

°

F

of the setting.

Allow the temperature to stabilize.

NOTE! There are arrows around

the screw indicating (H) to increase

and (L) to decrease the

temperature.

Set the knob indicator to 400

°

F

and allow the oven to reheat.

Remove the oven knob and push
out the silver center from the rear
of the knob and reinstall the knob

on the thermostat.

Continued from Previous Page

If the change is greater than 5

°

F

return to the bypass calibration.

Allow the temperature to stabilize.

The bypass setting must be

calibrated before calibrating the

oven thermostat.