beautypg.com

Roubleshooting – Southbend 436D User Manual

Page 34

background image

T

ROUBLESHOOTING

M

ODEL

400 R

ESTAURANT

R

ANGES

P

AGE

34

OF

64

O

PERATOR

S

M

ANUAL

1182299

REV

3 (05/05) D

RAFT

TROUBLESHOOTING

RANGE TOP BURNER

TROUBLESHOOTING

Remove each burner and check

that the venturi is clean and free of

buildup and debris.

Check that the burners are clean

and all ports are clear.

Check that the burners are set level

in the support brackets.

Common checks for all top

configurations.

CAUTION! Before raising or

removing Griddle Tops.

Remove the knobs and carefully

lower the top valve cover panel.

CAUTION! Wiring attached behind

panel.

Pull the Griddle thermostat

bulbs out of the tubes.

Remove the knobs and carefully

lower the top valve cover panel.

CAUTION! Wiring attached behind

panel on C.O. base models.

Check that each burner valve and

orifice is in alignment with the

burner.

Install a pressure tap in the main

gas line before the range pressure

regulator and install a manometer.

Shut off the main gas supply.

With each burner removed check
that the orifice size is correct and

clean and free of buildup and

debris.

Turn on the main gas supply.

Re-light all pilots.

Light all burners on the range.

NOTE: Leave the oven door open.

NOTE: Griddles and Hot Tops

must be raised and secured or

removed.

Observe the inlet pressure.

Inlet pressures for gases are:

Natural = 3.5" to 5" water column

Propane = 10" to 11" water column

Shut off the range burners and

main gas and remove the pressure

tap.

If the inlet pressure is low, all

equipment on the main gas line

should be lit and the pressure

adjusted.

Continues on next page.

NOTE: Griddle Tops