beautypg.com

Roubleshooting – Southbend 436D User Manual

Page 38

background image

T

ROUBLESHOOTING

M

ODEL

400 R

ESTAURANT

R

ANGES

P

AGE

38

OF

64

O

PERATOR

S

M

ANUAL

1182299

REV

3 (05/05) D

RAFT

TROUBLESHOOTING

TROUBLESHOOTING THERMOSTATIC GRIDDLE

Set the temperature to 300

°

F and

allow the griddle to reheat.

Refer to flowchart on page 35 for

burner troubleshooting.

THERMOSTATIC GRIDDLE

TROUBLESHOOTING

If no flame is established put a

soap and water mix to the orifice of

the burner to check for gas flow.

Turn the screw counter clockwise

to establish or increase the flame.

Put the bezels and knobs on the

griddle thermostats.

Set the griddle thermostats

to 300

°

F.

If no flame is established at the

bypass setting replace the

thermostat.

Reinstall the bezels and push out

the silver center of the knob from

the rear of the knob and reinstall.

Be sure the thermostat bulbs are

pushed completely into the tubes

under the griddle.

Remove the knobs and valve

cover panel.

Observe the burners while heating

griddle for poor operation.

Remove the knobs and bezel and

install the valve cover panel.

After griddle has heated for

approximately 20 minutes, observe

that the flame has decreased in

height.

Set the griddle knobs to the

midpoint between the two lines just

after the OFF position.

This is the bypass setting.

Check that there is a ¼ in. flame at

each port.

There is a slotted screw below the

stem on the thermostat valve.

If gas is flowing turn the bypass

screw until flame is set to

specifications.

Turn the screw clockwise to

decrease the flame.

If the flame is not correct remove

the knobs and bezel. See

illustration on page 32.

Continues on Next Page

CAUTION! WIRING BEHIND THE

PANEL.

This manual is related to the following products: