TROUBLESHOOTING

Turn on the gas supply to the

range.

Install a manometer on the

pressure tap.

Observe the manifold pressure.

Re-light the pilots and turn on all

the burners.

Manifold pressures are:

Natural gas = 4" water column

Propane gas = 10" water column

Shut off the range burners and

main gas and remove the pressure

tap.

If the pressure is low remove the

cap from the pressure regulator on

the back of the range.

With the gas supply shut off to the

range install a pressure tap on the

manifold in the plugged tap

provided.

Continued from Previous Page

Re-light the pilots.

Replace the pressure tap plug in

the manifold.

Test each burner.

If the flame is rising up off of the

ports adjust the burner shutter

closed.

Propane burners may have a small

amount of yellow tipping. This is

normal.

If the flame is long and yellow

adjust the burner shutter open.

Propane burners may have a slight

popping noise when turned off.

This is normal.

NOTE: Griddle and Hot Top

burners may be long and float

when cold. Allow the top to heat

before making burner adjustments.

Each burner should have a steady

blue flame on each port of the

burner.

Reinstall the top valve cover panel

and knobs.

Install the grates or griddle/hot

tops.

Install the thermostat bulbs into

griddle tops.

Be sure the capillary tubes are

away from burners, flames and

excessive heat.

Clockwise increases the pressure

and counter clockwise decreases

the pressure.