Power connection – Southbend SOUTH BEND LATHE CO.. SB1024 User Manual
Page 26
-24-
For Machines Mfg. Since 8/09
SB1024/SB1025/SB1026
P R E P A R A T I O N
Power Connection
SB1025 (220V 3-Phase)
Full Load Amp Draw ........................... 6/5.6 Amps
Required Voltage Range ................................ 220V
Phase ..........................................................3-Phase
Frequency ...................................................... 60 Hz
Minimum Circuit Size ............................. 15 Amps
Recommended Power Cord ...14 AWG/4C/300VAC
Recommended Plug/Receptacle ........ NEMA 15-15
Minimum Extension Cord Size ................ 14 AWG
Maximum Extension Cord Length ................ 50 ft.
SB1026 (220V)
Full Load Amp Draw ............................... 14 Amps
Required Voltage Range ................................ 220V
Phase ................................................. Single-Phase
Frequency ...................................................... 60 Hz
Minimum Circuit Size ............................. 20 Amps
Recommended Power Cord ...14 AWG/3C/300VAC
Recommended Plug/Receptacle .......... NEMA 6-20
Minimum Extension Cord Size ................ 14 AWG
Maximum Extension Cord Length ................ 50 ft.
To connect the mill to power:
1.
Make sure the incoming power source and
the power cord meet the requirements listed
above.
2.
Use the correct size strain relief when you
feed the power cord through the bottom of
the electrical cabinet.
3.
Terminate the power cord as illustrated in
the Electrical Box Wiring Diagrams on
Pages 65–68.
4. We recommend that you connect the other
end to a NEMA 6-20 plug.
Electrocution or fire
may occur if machine is
ungrounded, incorrectly
connected to power, or
connected to an undersized
circuit. Use a qualified
electrician to ensure a safe
power connection.
Once the machine is set up and assembled as
previously described in this manual, it is ready to
be connected to the power source.
Note About Extension Cords: Using an
incorrectly sized extension cord may decrease the
life of electrical components on the machine.
Note About 3-Phase Power: DO NOT use a
static phase converter to create 3-phase power—
it can quickly decrease the life of electrical
components on the machine. If you must use
a phase converter, only use a rotary phase
converter and connect the manufactured leg to
the correct power connection terminal, shown in
the wiring diagrams on Page 65.
SB1024 (220V)
Full Load Amp Draw ............................... 14 Amps
Required Voltage Range ................................ 220V
Phase ................................................. Single-Phase
Frequency ...................................................... 60 Hz
Minimum Circuit Size ............................. 20 Amps
Recommended Power Cord ...14 AWG/3C/300VAC
Recommended Plug/Receptacle .......... NEMA 6-20
Minimum Extension Cord Size ................ 14 AWG
Maximum Extension Cord Length ................ 50 ft.