JVC GM-H40L2A User Manual
Page 29
27
ENGLISH
COLOR TEMP.
Item
To do
Setting value
R DRIVE, G DRIVE,
B DRIVE
Adjusts the drive level of each color (red, green, and blue).
MIN
+= 000 += MAX (in
512 grades)
R CUT OFF, G CUT OFF,
B CUT OFF
Adjusts the cut-off point of each color (red, green, and blue).
MIN
+= 000 += MAX (in
512 grades)
sub menu
Displays the adjustment bar which enables you to adjust the drive level and cut-off point while
viewing the actual picture.
reset
Restores the default setting for all the items in “COLOR TEMP.”
NOTE
• Adjust the color temperature after selecting color temperature (HIGH, MID., LOW, or OTHER) on the main menu (see “PICTURE SETTING” on page
21).
NO SYNC FUNCTION
Item
To do
Setting value
NO SYNC DISPLAY
Selects the screen color (or sleep mode) when no signal is being
input.
OFF, SLEEP (sleep mode),
RED, GREEN, BLUE, GRAY
DELAY TIME
Sets the time to change the screen color (or sleep mode) set in
“NO SYNC DISPLAY” above after signals stops being input.
5s, 1min., 30min.
reset
Restores the default setting for all the items in “NO SYNC FUNCTION.”
REMOTE SYSTEM
Item
To do
Setting value
REMOTE IN SEL.
Selects the input terminal used for external control.
D-sub9, RJ-45
CNT. RJ45 OUT
Selects the external control method for RS-485 OUT terminal.
RS485, IR OUT
CNT. RJ45 IN
Selects the external control method for RS-485 IN terminal.
RS485, MAKE, TRIG., SET
PORT F1 – PORT F5
Assigns the control function to the RS-485 IN terminal’s pins (1 to
5) when selecting “SET” in “CNT. RJ45 IN” above.
INP. A – INP. F, POWER,
ASPECT, MUTING, PIP, PBP,
– – – (no function)
reset
Restores the default setting for all the items in “REMOTE SYSTEM.”
NOTE
• For details about external control, see pages 33 to 37.
SECURITY LOCK
Item
To do
Setting value
SECURITY LOCK
Activates/deactivates the Security Lock. When this function is
activated, the monitor cannot be turned on without entering the
password set in “PASS ID SETTING” below.
ON, OFF
PASS ID SETTING
Sets the password for the Security Lock.
4 characters
NOTE
• For details about the Security Lock, see page 32.
06-42_GM-H40L2A-f.indd 27
06-42_GM-H40L2A-f.indd 27
06.4.24 5:20:48 PM
06.4.24 5:20:48 PM