Cmun03013e source ckd management is disabled, Source, Remote – IBM TOTAL STORAGE DS8000 User Manual
Page 291: Mirror, Copy, Operation, Failure, Management, Disabled, Services

CMUN03012E
SOURCE
Remote
Mirror
and
Copy
operation
failure
Explanation
The
storage
management
console
server
reports
a
Remote
Mirror
and
Copy
error.
One
of
the
following
conditions
is
occurring:
v
Abnormal
conditions
exist
at
the
secondary
controller.
v
Abnormal
conditions
exist
at
the
secondary
storage
unit.
v
The
communication
paths
between
the
primary
and
remote
controller
are
not
functioning.
v
Communication
cannot
be
established
with
the
secondary
control
unit.
Action
Check
for
hardware
errors
and
disconnected
cables,
and
follow
the
recommended
service
procedure.
Check
the
status
of
the
secondary
system.
If
the
problem
persists,
contact
IBM
technical
support
for
assistance.
CMUN03013E
SOURCE
CKD
management
is
disabled.
Explanation
Management
of
count-key-data
resources
on
the
storage
unit
is
disabled.
Action
Contact
IBM
technical
support
for
assistance.
CMUN03014E
SOURCE
Copy
Services
operation
failure:
A
microcode
code
load
is
in
progress.
Explanation
A
microcode
code
load
is
in
progress,
and
no
other
activities
can
take
place
on
the
storage
unit.
Action
Wait
until
the
microcode
code
load
completes,
and
then
resubmit
the
task.
CMUN03015E
SOURCE
Operation
failure:
consistent
copy
would
be
compromised
Explanation
A
pause
or
end
Global
Mirror
fails
because
the
action
cannot
complete
without
compromising
the
consistent
copy
of
the
data.
Action
Contact
IBM
technical
support
for
assistance.
Chapter
7.
DS
storage
management
console
server
messages
271