¦ 47500 ¦ Part of the RAID array data ¦ Call for service ¦

¦ ¦ might have been lost. ¦ ¦

+---------+-------------------------------+------------------------------¦

¦ 48000 ¦ The SSA adapter has detected ¦ Go to "SSA Loop ¦

¦ ¦ a loop configuration that is ¦ Configurations that Are Not ¦

¦ ¦ not valid. ¦ Valid" in topic B.1 or call ¦

¦ ¦ ¦ for service ¦

+---------+-------------------------------+------------------------------¦

¦ 49000 ¦ A RAID array is in the ¦ Call for service ¦

¦ ¦ Degraded state because a disk ¦ ¦

¦ ¦ drive is not available to the ¦ ¦

¦ ¦ array, and a write command ¦ ¦

¦ ¦ has been sent to that array. ¦ ¦

¦ ¦ ¦ ¦

¦ ¦ A disk drive might not be ¦ ¦

¦ ¦ available for one of the ¦ ¦

¦ ¦ following reasons: ¦ ¦

¦ ¦ ¦ ¦

¦ ¦ The disk drive has ¦ ¦

¦ ¦ failed. ¦ ¦

¦ ¦ The disk drive has been ¦ ¦

¦ ¦ removed from the ¦ ¦

¦ ¦ subsystem. ¦ ¦

¦ ¦ An SSA link has failed. ¦ ¦

¦ ¦ A power failure has ¦ ¦

¦ ¦ occurred. ¦ ¦

+---------+-------------------------------+------------------------------¦

¦ 49100 ¦ A RAID array is in the ¦ Call for service ¦

¦ ¦ Exposed state because a disk ¦ ¦

¦ ¦ drive is not available to the ¦ ¦

¦ ¦ array. ¦ ¦

¦ ¦ ¦ ¦

¦ ¦ A disk drive can become not ¦ ¦

¦ ¦ available for several ¦ ¦

¦ ¦ reasons: ¦ ¦

¦ ¦ ¦ ¦

¦ ¦ The disk drive has ¦ ¦

¦ ¦ failed. ¦ ¦

¦ ¦ The disk drive has been ¦ ¦

¦ ¦ removed from the ¦ ¦

¦ ¦ subsystem. ¦ ¦

¦ ¦ An SSA link has failed. ¦ ¦

¦ ¦ A power failure has ¦ ¦

¦ ¦ occurred. ¦ ¦

+---------+-------------------------------+------------------------------¦

¦ 49500 ¦ No hot-spare disk drives are ¦ Call for service ¦

¦ ¦ available for a RAID array ¦ ¦

¦ ¦ that is configured for ¦ ¦

¦ ¦ hot-spare disk drives. ¦ ¦

+---------+-------------------------------+------------------------------¦

¦ 49700 ¦ The parity for the RAID array ¦ Call for service ¦

¦ ¦ is not complete. ¦ ¦

+---------+-------------------------------+------------------------------¦

¦ 50000 ¦ The SSA adapter failed to ¦ Exchange the adapter card ¦

¦ ¦ respond to the device driver. ¦ for a new one or call for ¦

¦ ¦ ¦ service ¦

+---------+-------------------------------+------------------------------¦

¦ 50001 ¦ A data parity error has ¦ Exchange the adapter card ¦

¦ ¦ occurred. ¦ for a new one or call for ¦

¦ ¦ ¦ service ¦

+---------+-------------------------------+------------------------------¦

¦ 50002 ¦ An SSA adapter DMA error has ¦ Exchange the adapter card ¦

¦ ¦ occurred. ¦ for a new one or call for ¦

¦ ¦ ¦ service ¦

+---------+-------------------------------+------------------------------¦

¦ 50004 ¦ Channel check. ¦ Exchange the adapter card ¦

¦ ¦ ¦ for a new one or call for ¦

¦ ¦ ¦ service ¦

+---------+-------------------------------+------------------------------¦

¦ 50005 ¦ A software error has ¦ Call for service ¦

¦ ¦ occurred. ¦ ¦

+---------+-------------------------------+------------------------------¦

¦ 50006 ¦ A channel check has occurred. ¦ Exchange the adapter card ¦

¦ ¦ ¦ for a new one or call for ¦

SSA RAID Adapter Installation and User's Guide.

Appendix B. SSA RAID Adapter Service Request Numbers

_ Copyright IBM Corp. 1996

B.0 - 3