An assembler program that calls DFSMS callable services
*ASM XOPTS(CICS,NOEPILOG,SP)
*
*
A program that can be run as a CICS transaction to Read and Set
*
the BWO Indicators and BWO Recovery Point via DFSMS Callable
*
Services (IGWABWO).
*
*
Invoke the program via a CICS transaction as follows:
*
*
Rxxx ’data_set_name’
*
Sxxx 100 ’data_set_name’
*
*
Where:
*
Rxxx and Sxxx are the names of the transactions that will invoke
*
this program. Specify Rxxx to read and Sxxx to set the BWO
*
attributes.
*
’data_set_name’ is the fully-qualified name of your data set
*
100 is the value the BWO indicators will be set to.
*
The BWO Recovery Point time will be set to the current date and
*
time returned from the CICS ASKTIME function.
*
DFHEISTG DSECT
INDATA
DS
0CL53
Input data stream
*
* First character of tran id indicates transaction function
*
TRANFUNC DS
C
First char of tran id - S=SET R=READ
DS
4C
Remainder of tran id and space
BWOC1
DS
C
First BWO indicator
BWOC2
DS
C
Second BWO indicator
BWOC3
DS
C
Third BWO indicator
DS
C
Space
DSNAMES
DS
44C
Target data set name 1-44 chars
*
* 2 possible formats of input line, so overlay the definitions
*
ORG
INDATA
DS
5C
Tran id and space
DSNAMER
DS
44C
Target data set name 1-44 chars
DS
4C
Filler
*
INLENGTH DS
H
Length of input data stream
*
* Parmlist for IGWABWO call
*
PARMLST
DS 10A
RETCODE
DS
F
Return code
REASON
DS
F
Reason
PROBDET
DS
D
Problem determination code
FUNC
DS
F
Function
READ
EQU
0
Read
SET
EQU
1
Set
DSNLEN
DS
F
Data set name length
DSN
DS
44C
Data set name
BWOFLAGS DS
03F
BWO indicator flags
ORG
BWOFLAGS
BWOF1
DS
F
BWO indicator 1
BWOF2
DS
F
BWO indicator 2
BWOF3
DS
F
BWO indicator 3
BWOTIME
DS
D
BWO recovery point time
RESERVED DS
2D
Reserved
*
* Success message
*
SUCMSG
DS 0CL66
Define storage for success message
218