050

IDE Drive 0
Error

Hard disk connection
board

Hard disk drive

Planar board

054

IDE Drive(s)
Disabled

Hard disk drive cable

Hard disk drive

056

IDE Drive 0
Auto Detection
Failed

Hard disk connection
board

Hard disk drive

Planar board

070

Real Time
Clock Error

Reset time in the
"Basic System Set-
tings" menu of the
BIOS Utility.

Backup battery (RTC
battery)

Planar board

071

CMOS Battery
Bad

Enter BIOS Utility and
execute "Load Setup
Default Settings".

Backup battery (RTC
battery)

Planar board

072

CMOS
Checksum
Error

Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.

Backup battery (RTC
battery)

Planar board

006

Equipment
Configuration
Error

Ensure the equipment
(diskette drive, hard
disk drive, keyboard,
external mouse, etc.) is
connected properly
and is correctly set in
the BIOS Utility.

Hard disk connection
board

Hard disk drive

Planar board

System Operation (Runtime)

103

Press

<

Esc>

to turn off NMI
or other key to
reboot

Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.

Remove the non-
factory-installed
adapter card and
reboot the system.

18