beautypg.com

Ir emitter placement (netcommand) – MITSUBISHI ELECTRIC LT-40133 User Manual

Page 51

background image

6. NetCommand

51

IR Emitter Placement (NetCommand)

An IR emitter cable is included with LT-40134, LT-46144, and

LT-52144 TV models only.

The NetCommand system uses emitters connected to

the

IR EMITTER jack to control other devices such as

DVD players, cable boxes, satellite receivers, and VCRs.

1. Connect the plug end of the supplied IR emitter

cable to the

IR EMITTER NetCommand

®

jack on the

TV back panel #2 (in recessed area).

2. Run the cable for each of the emitter ends under,

alongside, or over each device to be controlled so
that the emitter end is in front of the area where the
remote control sensor is located.

3. Position the emitter end with the emitter bulb facing

the remote control sensor. The bulb emits infrared
light in a cone-shaped pattern. Place the bulb far
enough from the sensor to allow the cone pattern
to reach the sensor.

The IR sensor is usually behind the plastic window

of the front display panel. It is sometimes visible
with the aid of a flashlight and is normally a round
or square cutout behind the plastic. If you cannot
see the sensor and the device’s Owner’s Guide
does not specify the location, you can find it by
following these steps using the device’s remote
control:
a. Hold the device’s remote about one-half inch

from the front of the device. Starting from one
end of the display window plastic, press the
POWER button.

b. If the device does not respond, move the

remote control one inch toward the center and
try again.

c. Repeat this until the device responds.
d. Note this location and then start over from the

other end of the display window plastic, repeat-
ing until the device responds again.

The remote control sensor is somewhere

between these two positions. This is usually
enough accuracy for placement of the IR emit-
ters.

With some devices, the emitter works better
facing downward from the top of the device.
Experiment to find what works best.

4. Secure the emitter ends in place using double-

sided tape.

5. Place any unused ends behind the devices to

prevent stray signals from reaching the IR sensors.

#"$,*/1651"/&-
CFMPXMBCFMXJUIJOSFDFTTFE
BSFBBUUPQ

57#BDL1BOFM

% * ( * 5 " -

4 6 3 3 0 6 / %

4

$)

"73FDFJWFS

0UIFS"7EFWJDF

Connecting IR Emitter NetCommand

*OGSPOUPGB
TJOHMFBWFSBHF
TJ[FEEFWJDF

0OUPQPGBTJOHMF

UBMMEFWJDF

*OGSPOU TIBSFE
CZUXPBWFSBHF
TJ[FEEFWJDFT

*3TFOTPS

*3TFOTPS

*3TFOTPS

*3TFOTPS

Place IR emitters so the signal can be “seen” by the IR
sensor on each device.

IMPORTANT

Position IR emitters so that each device’s
sensor “sees” the signal from only one emitter.
Otherwise, a device receiving signals from
multiple sources (remote controls, IR emitters)
may not respond at all.

This manual is related to the following products: