beautypg.com

Moxa Technologies NPort 5600 User Manual

Page 65

background image

NPort 5600 Series User’s Manual

Configuring NPort Administrator

5-35

DCD changed

The DCD (Data Carrier Detect) signal has changed, also indicating that the modem connection
status has changed. For example, a DCD change to high also means “Connected” between local
modem and remote modem. If the DCD signal changes to low, it also means that the connection
line is down.

When the DCD changes, NPort 5610 will immediately send an e-mail or send an SNMP trap.

DSR changed

The DSR (Data Set Ready) signal has changed, also indicating that the data communication
equipment’s power is off. For example, a DSR change to high also means that the DCE is powered
ON. If the DSR signal changes to low, it also means that the DCE is powered off.

When the DSR changes, NPort 5610 will immediately send an e-mail or send an SNMP trap.


Mail

Setting

Factory Default

Necessity

Enable, Disable

Disable

Optional

This feature helps the administrator manage how the NPort sends e-mail to pre-defined e-mail
boxes when the enabled events—such as Cold start, Warm start, Authentication failure,
etc.—occur. To configure this feature, click the Event Type Mail checkbox.

Trap

Setting

Factory Default

Necessity

Enable, Disable

Disable

Optional

This feature helps the administrator manage how the NPort sends SNMP Trap to a pre-defined
SNMP Trap server when the enabled events—such as Cold start, Warm start, Authentication
failure, etc.—occur. To configure this feature, click the Event Type Trap checkbox.

ATTENTION

DCD changed and DSR changed event only supported by those models, which have these two
signals. For example NPort 5210, 5410 and NPort 5610.