Specifications, Model ble100s – Motorola BLE100 User Manual
Page 44
BLE100 Installation and Operation Manual
Appendix A
Specifications
Specifications are valid over the given passband and operating temperature range of
−40°F to
+140
°F (−40°C to +60°C). Specifications stated are worst case unless otherwise noted, and are
subject to change. Refer to the Motorola CHS web site or contact your account representative for
the latest specifications.
Model BLE100S
Specification Forward
Amplifier
Passband (S-split)
52 through 1003 MHz
Gain
Full
38 dB (with SFE-100-*)
Operational
34 dB (with SFE-100-* and slope reserves)
Flatness
52 through 1003 MHz
±0.70 dB maximum
Level control, automatic
Bode board using ADU/QADU
Gain control
Fixed pads, JXP-
∗B
Performance - reference frequency
(MHz)
1003/550/52
at typical output (dBmV)
45/44/37
Channels
79 analog/320 MHz digital (suppressed by 6 dB)
Crossmod
–70 dB
CTB
–76 dB
CSO
–71 dB
Noise figure
at 52 MHz
8 dB (with SFE-1) maximum
at 1003 MHz
8 dB (with SFE-1) maximum
Interstage equalizer, LDR/9/1G
9
±1 dB
Hum modulation
–65 dB
Return loss, input/output
16 dB minimum at operational level
Test points, input/output
20
±1.0 dB
Housing dimensions
10.6 L
× 8.0 W× 4.7 D inches (26.9 Ч 20.3 Ч 11.9 cm)
Weight
7.2 pounds (3.2 kg)