Gaskets
Each housing is equipped with a recessed woven-wire RF gasket and a silicone-rubber gasket to
provide a seal between the housing base and lid. These gaskets provide efficient ground
continuity, RF shielding, and weather protection. Both gaskets must be in place and in good
condition to ensure proper operation and protection of the station. The weather gasket should be
lightly coated with silicone grease each time the BLE100 is opened. Replace this gasket if it
becomes damaged or deformed.
Figure 2-4
Housing gaskets