4-2

Bench Testing

BLE100 Installation and Operation Manual

Test Equipment and Connections

The equipment typically used for testing the BLE100 consists of a network analyzer such as the
HP 8712 or 8713 series, a 60/90 Vac bench power supply, a cable simulator, a Motorola model
SSP-PIN power combiner, and a variety of jumper cables, adapters, and fittings.

CAUTION!

To protect the network analyzer and sweep comparator, you must configure the SSP-PIN power combiner to block ac
power from the input port.

Fabricate a cable simulator that you can configure to provide the desired cable loss in 1 dB
increments up to approximately 30 dB. Then, connect the test equipment as shown in
Figure 4-1:

Figure 4-1
Test equipment connections for bench sweeping

AS

SE

MBLE

D

IN

M E X I C

O

4

2

6

3

1

5

Network

analyzer

BLE100

under test

Cable

simulator

Power

combiner

117

Vac

AC power

supply

60/90 Vac

Sweep

input

Sweep

output

CAUTION!

Before you begin the following subsection, remove the input pad,

JXP

-

IN

, to avoid damage to the hybrids before you

apply power.

Measuring Forward Gain

This subsection provides instructions for measuring the full gain and the operational gain and
flatness of the BLE100.

To measure the full gain of the amplifier:

1

Determine whether the power-supply jumper (J1) is positioned for

LO

or

HI

operation.

2

Connect the BLE100 to the test equipment as illustrated in Figure 4-1 and apply power.

3

Verify that the dc voltage is 24 V

± 0.4 V and re-install the input pad.

4

Apply the sweep signal and adjust test equipment as needed.

5

Select manual gain by placing the drive control select jumper in the

MAN

position and turn

the

MANUAL LEVEL

control (Figure 2-8) fully clockwise.