INSTALLING ABOVE 2000 FEET

• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations

(at the factory).

• In Canada, these appliances are certified for altitudes of 0 – 4,500 ft.

ORIFICE SIZES, PRESSURES AND BTUs

NATURAL GAS

PROPANE GAS

Manifold Press: (W.C.)

3.5"

Manifold Press: (W.C.)

10"

Maximum Supply Pressure

10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

BEFORE YOU START

Read this homeowner

's

manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and

immediately inform

Spark Modern

if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts.

ITEMS REQUIRED FOR INSTALLATION
Tools:

Building Supplies:

• Phillips Screwdriver

• Framing Materials

• Hammer

• Wall Finishing Materials

• Saw and/or saber saw

• Caulking Material (

Non-combustible

)

• Level

• Fireplace Surround Material

(Non-combustible)

• Measuring Tape

• Piping Complying with Local Codes

• Electric Drill and Bits

• Tee Joint

• Pliers

• Pipe Sealant Approved for use with Propane/LPG

• Square

(Resistant to Sulfur Compounds)

• Pipe Wrench

Model

Gas

Orifice Size

Input Rate, Btu/hr

Number

Type

As Shipped

Max

Min

91N - SeeThru Natural #31

39,000 27,000

91P - SeeThru Propane #49 38,000 27,000

92N - Peninsula Natural #31

39,000 27,000

92P - Peninsula Propane #49 38,000 27,000