Venting installation – Mastic Spark Modern Fires 91P User Manual

Page 17

background image

16

L100001

17

�������

�������

������

�������

Figure 12 - Vent Opening Requirements

Note: Horizontal runs of vent must
be supported every three feet
(914mm). Use wall straps for this
purpose.

Figure 13 - Rigid Vent Pipe Connections

Female Locking Lugs

Male Slots

REAR WALL VENT INSTALLATION

When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind

the appliance with 3' of vertical rise minimum.

• The maximum horizontal distance between the rear of the appliance and the outside of termination is 20" (508 m). See

Figure 11.

NOTE: A 30° elbow on 2 foot minimum vertical pipe is required for this configuration.

VENTING INSTALLATION

1. Locate and cut the vent opening in the wall. For com-

bustible walls first frame in opening. See Figure 11.

Combustible Walls:

Cut a 9

1

2

" H x

9

1

2

" W

(

241mm x 241mm

) hole through the exterior wall

and frame as shown. See Figure 12.

Noncombustible Walls:

Hole opening should be

7

1

2

" (190mm) in diameter.

2. Rigid vent pipes and fittings have special twist-lock

connections. Assemble the desired combination of
pipe and elbows to the appliance adaptor with pipe
seams oriented towards the wall or floor.

Twist-lock Procedure:

The female ends of the pipes

and fittings have three locking lugs (indentations).
These lugs will slide straight into matching slots on
the male end of adjacent pipes and fittings. Push
the pipe sections together and twist one section
clockwise approximately one-quarter turn until the
sections are fully locked. See Figure 13.

3. Attach vent pipe assembly to the fireplace. Set fire-

place in front of its permanent location to insure
minimum clearances. Mark the wall for a

9

1

2

"H

x

9

1

2

"W (

241mm x 241 mm

) rectangle hole (for

noncombustible material such as masonry block or
concrete, a 7

1

/

2

" [190mm] diameter hole is accept-

able). See Figure 11. The center of the hole should
line up with the center line of the horizontal rigid
vent pipe end. Be sure to allow for minimum rise. Cut a

9

1

/

2

"x

9

1

/

2

" (

241mm X 241mm

) rectangle hole through combustible

exterior wall (7

1

/

2

" [190mm] diameter hole if noncombustible). Frame as necessary. Allow

1

/

4

" minimum rise per foot. See

Figure 12.

Figure 11 - Rear Vent Application,

Maximum Horizontal Distance

Maximum

20"