VENT INSTALLATION

Figure 7 - Combustible Clearances for Vent Pipe

A Minimum of 4" Clearance to the Top Is

Required Along Horizontal Length of Pipe until

Flue Pipe Goes Through Nearest Wall.

WARNING

This fireplace must be vented to the outside. The venting system must NEVER be attached
to a chimney serving a separate solid

-fuel burning appliance. Each gas appliance must

use a separate vent system. Do not use common vent systems.

WARNING

Horizontal sections of this vent system require
a minimum clearance of

4

" from the top of

the pipe and 1" minimum to the sides and
bottom. Vertical sections of this system require
a minimum of 1" clearance to combustible
materials on all sides of the pipe.

WARNING

1" Clearance Is Acceptable

at the Outside Wall.

6

6

4

" minimum

1

" minimum

2'

pipe

Basic Horizontal Vent

Installation