Clearances, Warning – Mastic Spark Modern Fires 91P User Manual
Page 11
10
L100001
11
CLEARANCES
CLEARANCES TO COMBUSTIBLES
(both sides)
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/
4
" from the facing. If it does, it is
considered a mantel and must meet the mantel requirements listed in this manual.
Figure 6 - Clearances
Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or non-combustible material panel extending full width and depth of
the appliance.
WARNING
Clearance to
Combustibles
Sides
0
Floor
0
Back
0.5"
Standoff
0"
Front
36"
The fireplace face must be
completely covered with
any non-combustible ma-
terial. Allow clearance for
removal of front air panel