CLEARANCES

CLEARANCES TO COMBUSTIBLES

(both sides)

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than

3

/

4

" from the facing. If it does, it is

considered a mantel and must meet the mantel requirements listed in this manual.

Figure 6 - Clearances

Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or non-combustible material panel extending full width and depth of
the appliance.

WARNING

Clearance to

Combustibles

Sides

0

Floor

0

Back

0.5"

Standoff

0"

Front

36"

The fireplace face must be

completely covered with

any non-combustible ma-

terial. Allow clearance for

removal of front air panel

This manual is related to the following products: