Fp2073 bldv controls – Monessen Hearth BLDV7 SERIES BLDV500N/PV7;N/PSC7 User Manual
Page 5
74D3000
5
BLDV7 Series Gas Fireplace
proDuCt FeatureS
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home appr-oved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
proDuCt SpeCIFICatIonS
FP2073
BLDV controls
Off/Pilot/On Knob
Figure 1 -
BLDV7 Series Fireplace
(Millivolt Control shown)
Hi/Lo Knob
On/Off/RS
Switch
Ignitor
FP073
hIGh eLeVatIonS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
GaS preSSureS
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
GaS SpeCIFICatIonS & orIFICe SIZe
Max.Input Min. Input
Orifice
Model
Fuel
BTU/h
BTU/h
Size
BLDV400NV7
Nat.
6,000
1,000
.5 mm
BLDV400PV7
LP
6,000
1,000
1/16 in.
BLDV400NSC7 Nat.
6,000
19,000
.5 mm
BLDV400PSC7
LP
6,000
1,000
1/16 in.
BLDV500NV7
Nat.
8,000
0,000
#38
BLDV500PV7
LP
7,000
,000
1.55 mm
BLDV500NSC7 Nat.
8,000
0,000
#38
BLDV500PSC7
LP
7,000
,000
1.55 mm