74D3000

36

BLDV7 Series Gas Fireplace

BLACK

BLACK

WHITE

GREEN

BLACK

BLACK

WHITE

Receptacle 

Junction 

Box

120VAC

Speed Control 

FP2685
BLOTSDV blower wiring

optIonaL Fan BLower SySteMS

BLotSDV autoMatIC therMoStat BLower

Figure 51 -
BLOTSDV Blower Wiring Diagram

FP685

Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance
with prevailing codes.