beautypg.com

Monessen Hearth BLDV7 SERIES BLDV500N/PV7;N/PSC7 User Manual

Page 40

background image

74D3000

40

BLDV7 Series Gas Fireplace

SIGnature CoMManD SySteM operatIon InStruCtIonS

SySteM ConFIGuratIon/Setup

All System configuration/setup is done on the Command Center.
note: When using On/Off wall switch, the switch must be in the ON position to perform all configura-
tion set ups at the command center.
Intermittent/Standing pilot Setup (Default intermittent)
1. Holding the ON button on the Command Center while turning on the master switch will toggle be-

tween standing pilot and intermittent pilot.

. After the above operation, one beep (for standing pilot) or two beeps (for intermittent pilot) will be

given as confirmation.

Six-hour Safety Shutdown option (Default on)
1. The system comes preset from the factory with a six (6) hour shutdown from its last command of

operation. This is done to prevent the fireplace from continuing to operate if unattended. You may
disable this feature if you wish.

note: By disabling this feature, your fireplace may continue to operate unattended.
. When the master switch is in the ON position (“-”), pressing the ON button and the OFF button

on the Command Center simultaneously will toggle between enabling and disabling the six-hour
shutdown option.

3. After the above operation, one beep (for enabling the six-hour shutdown option) or two beeps (for

disabling the six-hour shutdown option) will be given as confirmation.

remote transmitter Learn Function (Default oFF)
1. The RF receiver button located on the Control Board must be in the on position before the learn

function can begin. Use paper clip to depress button. One beep for RF receiver ON or two beeps
for RF receiver OFF will be given as confirmation. Refer to Figure 57 for location.

. After the RF receiver is on, holding the OFF button on the Command Center while turning on the

master switch will activate the learn function for the transmitter.

3. After the above operation, two beeps will be given and the green LED on the Command Center will

flash for 10 seconds.

4. During the 10 seconds, press the OFF button on a transmitter to learn. Another two beeps will be

given to confirm a successful learning. Refer to transmitter instructions for remote operations.

Shutting off the Standing pilot (temporary Shut off)
To shut off the standing pilot for service or summer shut down, press and hold the ON button on the
Command Center for 3 seconds when the master switch is in the ON position (“-”) and the main burner
is off.
note: Pilot will resume the next time system is turned on.

Key Combinations for System Settings

note: When On/Off wall switch is used, it must be in the On position to perform all system setups.

Function

operation

Default Setting

Intermittent/Standing

Hold the ON ▲ button while turning on the master switch

Intermittent

Pilot Setup

(Beep once for standing pilot, twice for intermittent pilot)

Pilot

Standing Pilot Temp.

Hold the ON ▲ button 3 seconds (when the master switch

Shutoff

on the main burner is off)

RF Remote Receiver

Push the RF receiver On/Off button on the control board

RF OFF

On/Off

Beep once for ON and beep twice for OFF

Learn Remote

Hold the OFF ▼ button while turning on the master switch

Transmitter

(Beep twice then press any handheld remote button)

6-hour safety

Press the ON ▲ button and OFF ▼ button simultaneously

ON

shutdown setup

(Beep once for ON, twice for OFF)

This manual is related to the following products: