BLDV7 Series Gas Fireplace

Vent InStaLLatIon

w

arn

In

G

horizontal sections of this vent system require a minimum of 3" clearances
to combustibles at the top of the flue and 1" clearance at the sides and
bottom until the flue penetrates the outside wall.
a minimum 1" clearance
all around the flue is acceptable at this point of penetration.
If the vertical rise is 7

1

/

2

ft. or more, only a 1" clearance is needed on top

of any horizontal run.
Vertical sections of this vent system require a minimum of 1" clearance to
combustibles on all sides of the pipe.

Figure 11 -
Combustible
Clearances for Vent
Pipe

12”

1”

1”

3”

FP2338
min. vent clear

A minimum of 3" clearance
to the top is required along
horizontal length until flue
pipe penetrates outside
wall.

A minimum 1" clearance
t o c o m b u s t i b l e s
permitted all around
flue at outside wall

Vertical Rise Required
Before Horizontal Run

FP338