CFX Vent Free Fireplace System

20301726

FP2110a
fireplace locations
12/08

Carefully select the best location for installation of your unvented fireplace. The following factors should
be taken into consideration.

Clearance to side wall, ceiling, woodwork and window or other combustibles. Refer to Clearances

and Height Requirements section on Page 10. Minimum clearances to combustibles must be main-
tained.

Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air reg-

isters for forced air furnaces/air conditioners, windows or doors.

Installation must provide adequate ventilation and combustion air.

DO NOT INSTALL THE CFX MODEL IN A BEDROOM OR BATHROOM.

Location should be out of high traffic areas and away from furniture and draperies due to heat from

firebox.

Never obstruct the front opening of the unvented fireplace or restrict the flow of combustion and

ventilation air.

Do not install in the vicinity where gasoline or other flammable liquids may be stored. The unvented

firebox must be kept clear and free from the combustible materials.

Figure 4 -
Suggested Locations

FP2110a

FIREPLACE INSTALLATION