beautypg.com

Cfx vent free fireplace system – Monessen Hearth CFX24 User Manual

Page 4

background image

4

CFX Vent Free Fireplace System

20301726

IMPORTANT SAFETY INFORMATION

18. During manufacturing, fabricating and shipping, various

components of this appliance are treated with certain
oils, films or bonding agents. These chemicals are not
harmful but may produce annoying smoke and smells
as they are burned off during the initial operation of the
appliance; possibly causing headaches, or eye or lung
irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear
with continued use.

19. Input ratings are shown in BTU per hour and are for

elevations up to 2,000 feet. For elevations above 2,000
feet, input ratings should be reduced 4 percent for each
1,000 feet above sea level. Refer to the National Fuel
Gas Code.

20. The appliance and its appliance main gas valve must

be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures in excess of 1/2 psig (3.5 kPa).

This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

CODES

Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE
ANSI Z223.1 or NFPA54 which can be obtained from…

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

or

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

21. The appliance must be isolated from the gas supply

piping system by closing its equipment shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa).

22. Do not use this room heater if any part has been under

water. Immediately call a qualified service technician
to inspect the room heater and to replace any part of
the control system and any gas control which has been
under water.

23. Never burn solid fuels in a fireplace where a unvented

room heater is installed.

24. Always have a fireplace screen in place when the

appliance is in operation, and unless other provisions
for combustion air are provided, the screen shall have
an opening(s) for induction of combustion air.

25. Do not fill spaces around the firebox with insulation or

other materials. These spaces must be maintained to
prevent the firebox from coming in contact with com-
bustible materials.

This manual is related to the following products: