ENGLISH

SECTION 2 - INSTALLATION

WARNING

Keep the appliance area free and clear of combustibles.

WARNING

Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no

obstructions around or underneath the oven. Constructional changes to the area where the oven is

installed shall not affect the air supply to the oven.

CAUTION

For additional installation information, contact your local Authorized Service Agent.

NOTE

There must be adequate clearance between the oven and combustible construction. Clearance

must also be provided for servicing and for proper operation.

NOTE

An electrical wiring diagram for the oven is located inside the machinery compartment.

NOTE

Four casters are provided to allow the oven to be more easily moved to the installation location. These

casters are intended to simplify pre-installation movement only, and are NOT suitable for use as part of the

oven installation. During the installation procedure, the casters MUST be removed, so that the oven can be

supported by the supplied 152mm adjustable legs.

NOTE

All aspects of the oven installation, including placement, utility connections, and ventilation requirements,

must conform with any applicable local, national, or international codes. These codes supercede the require-

ments and guidelines provided in this manual.

WARNING

The oven must be installed on an even (level) non-flammable flooring and any adjacent walls must

be non-flammable. Recommended minimum clearances are specified in the Description section of

this Manual.

WARNING

For electric ovens, after any conversions, readjustments, or service work on the oven, check that the

ventilation system (if so equipped) is in operation.

WARNING -

For gas ovens, after any conversions, readjustments, or service work on the oven:

•

Perform a gas leak test.

•

Test for correct air supply.

•

Test for proper combustion and gas supply.

•

Check that the ventilation system is in operation.