Trigger mode, Trigger mode -8 – Motorola LS3578 User Manual
Page 82
5 - 8
Symbol LS3578 Product Reference Guide
Trigger Mode
Scan one of the following bar codes to set the scanner’s trigger mode.
Level Trigger
Upon trigger pull, an aiming dot appears for a programmable duration of time. After this time, the aiming dot turns
into a standard laser scanning beam for a full decode session. The laser scanning beam stays on until the laser-on
timeout occurs, a decode occurs, or the trigger is released. If the trigger is released before the aiming duration
expires, the laser shuts off and no decode occurs.
*Level
Two Stage - Option 1
Upon trigger pull, an aiming dot appears. This aiming dot remains while the trigger is pulled. When the trigger is
released, the aiming dot turns into a standard laser scanning beam for a full decode session. The laser scanning
beam stays on until the laser-on timeout occurs or a decode occurs. If the trigger is pulled again while in a decode
session, the scanner beam returns to an aiming dot.
Two Stage - Option 1
Two Stage - Option 2
Upon trigger pull, an aiming dot appears. When the trigger is released, the aiming dot turns off. Pulling the trigger
twice quickly turns on the standard laser scanning beam for a full decode session. The laser scanning beam stays
on until the laser-on timeout occurs, a decode occurs, or the trigger is released.
Two Stage - Option 2