Motorola LS3578 User Manual
Page 40
3 - 4
Symbol LS3578 Product Reference Guide
Scanner emits short low-short
high- short low-short high beep
sequence while it is being
programmed.
Out of ADF parameter
storage space.
Erase all rules and re-program with shorter rules.
Out of Synapse parameter
storage space.
Scan
Set Synapse Defaults
code, from the
appropriate Synapse Interface Guide, for cables
no longer in use and re-program the scanner for
the current host interface.
Scanner emits one short high
beep when it is not in use.
In RS-232 mode, a
character is received and
Beep on
enabled.
Normal when Beep on
scanner is in RS-232 mode.
Cradle does not work after
following installation
procedures.
Cradle is not receiving
power.
Check system power.
Cable connections are not
secure.
Reinsert cables properly.
The scanner is not inserted
properly in the cradle.
Reinsert scanner.
Cradle is not properly
connected to the host.
Check that host settings are correct, and connect
the cradle to the appropriate port on the host.
Battery does not charge.
Cradle is outside the
charging temperature range.
Charge within the recommended temperature of
32° to 104° F (0° to 40° C) nominal, 41° to 95° F
(5° to 35° C) ideal.
Table 3-1
Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
NOTE
If problems still occur, contact the distributor or Motorola Enterprise Mobility Support. See
contact information.