32

Check of installation of the horizontal vane

E

Replace the
indoor electronic
control P.C. board.

Replace the
interlock switch(Fan).

Is the stopper of the horizontal vane
locked to the indoor unit correctly?

Yes

No

Is there resistance 0

"

?

Relock the stopper of the
horizontal vane to the indoor unit.
(Refer to 10-1.5.)

Yes

Are all lamps flashing?

Yes

No(

)

No

OK

Turn ON the
power supply.

To check the continuity of the interlock switch
(Fan), measure the resistance of connector

1

-

2

connected to CN1R1 on the indoor electronic
control P.C. board.

Turn OFF the
power supply.

Turn OFF the
power supply.

All lamps flash ON and OFF every 0.5-second.
Indoor unit and outdoor unit do not operate.

Check of PLASMA operation

F

PLASMA lamp flashes 2-time.

POWER lamp flashes 1 to 5 times while PLASMA operation failure mode (Refer to 10-2.5) is recalled.

After performing the check, make sure to release the failure mode recall function.

w

2 Turn PLASMA operation OFF and ON again.

(For turning OFF PLASMA operation, refer to 10-2.3.)
(If it goes normal without turning OFF and ON, PLASMA lamp doesn't go OFF.)

High voltage (approx. -4.4 kV) is generated during PLASMA
operation.
Pay careful attention and never touch PLASMA ELECTRODE
UNIT and the high-voltage lead part (red wire).

Yes

No

OFF

PLASMA
operation

Continuously blinking.

Does PLASMA lamp flash
2-time with unit stopping?

Turn ON the power supply.

Replace the indoor electronic control P.C. board.

1

While pressing both OPERATION SELECT button and

TOO COOL button on the remote controller at the same time,
press RESET button.

2

First, release RESET button.

And release the other two buttons after all LCD except the set

temperature in operation display section of the remote
controller is displayed after 3 seconds.

3

Press OPERATE/STOP (ON/OFF) button (the set temperature

is displayed)

4

And press PLASMA button once with the remote controller

headed towards the indoor unit.

w

1

PLASMA operation is selected.

w

The plasma operation check mode is set.(Refer to 10-2.5.)

Does PLASMA lamp stay OFF, or continuously
blink?

Replace the PLASMA POWER P.C. board.

w

1 Regardless of normal or abnormal condition,

a short beep is emitted once the signal
is received.

Normal