10-5. TROUBLE CRITERION OF MAIN PARTS

MSZ-FD25VA MSZ-FD25VAS MSZ-FD35VA MSZ-FD35VAS

Part name

Figure

Check method and criterion

Measure the resistance with a tester.

Refer to 10-7. "Test point diagram and voltage", "Indoor electronic control
P.C. board", the chart of thermistor.

Room temperature
thermistor(RT11)

Indoor coil thermistor
(RT12, RT13)

Horizontal vane
motor(MV1)

Normal

BRN-other one

Measure the resistance between the terminals with a tester.
(Part temperature 10 ~ 30

°

C)

336

"

~ 364

"

Color of the lead wire

Vertical vane
motor(MV2)
i-see Sensor
motor(MT)

Normal

Measure the resistance between the terminals with a tester.
(Part temperature 10 ~ 30

°

C)

i-see Sensor(RR)

Cover the i-see Sensor with black vinyl tape. Then, turn ON the power
supply. (i-see Sensor is energized.) Measure the voltage between
connector terminals of i-see Sensor with a tester.
(Part temperature 10 ~ 40

°

C)

282

"

~ 306

"

Normal range

2

(GND) -

4

(+)

1

(+) -

2

(GND)

1.874 ~ 3.387 VDC
1.010 ~ 1.420 VDC

i-see Sensor
connector terminals

NOTE: Pay attention to static electricity.

Indoor fan motor(MF)

Check 10-6.

A

.

PLASMA electrode unit

Check 10-6.

F

Color of the lead wire

BRN-other one

RED

YLW
BRN

ORN

GRN

ROTOR

RED

YLW
BRN

ORN

GRN

ROTOR

Cover the i-see
Sensor with
black vinyl tape.

i-see Sensor

i-see Sensor P.C. board

Black vinyl tape

connector

w

4
3
2(GND)
1

OBH488-1.qxp 07.8.9 11:47 AM Page 27