MITSUBISHI ELECTRIC MSZ-FD25VAS User Manual
Page 17
Operation and operating range
i-see sensor moves 30 degrees from the center in both right and left side.
i-see Sensor operates as follows in accordance with AREA setting made with the remote controller.
“AUTO” in AREA setting; first turning to the LEFT for adjusting the position then.....
CENTER
RIGHT
CENTER
LEFT
CENTER......
(The sensor turns to the right, left and center.)
“RIGHT” in AREA setting; first turning to the LEFT for adjusting the position then....
CENTER
RIGHT
CENTER
RIGHT
CENTER......
(The sensor turns to the right and center.)
“LEFT” in AREA setting; first turning to the LEFT for adjusting the position then....
CENTER
LEFT
CENTER
LEFT
CENTER......
(The sensor turns to the left and center.)
The sensor finishes turning to one area to another for 3 seconds and it operates one area for 5 seconds.
17
(1) Press OPERATE/STOP (ON/OFF) button to start the air conditioner.
(2) Press PLASMA button to set PLASMA operation.
PLASMA lamp turns ON and plasma electrode unit is energyzed.
(3) Press PLASMA button again to cancel PLASMA operation.
9-8. PLASMA ( ) OPERATION
Description of PLASMA operation:
Plasma operation consists of deodorizing and air purifying features.
Particles of odor-releasing substances are absorbed and decomposed by the plasma deodorizing filter.
Particles of allergens such as pollens and house dust are collected by the plasma anti-allergy filter.
These filters work with negative ions generated by the plasma electrode unit.
i-see Sensor turning to the right
i-see Sensor turning to the center
i-see Sensor turning to the left
OBH488-1.qxp 07.8.9 4:06 PM Page 17