Multi-Tech Systems ISI5634PCI/4/8 User Manual
Page 86

86
ISI5634PCI/4/8 User Guide
Command: &Zy=x Store Dialing Command
Values:
y = 03 (callback security disabled) or 029 (callback
security enabled)
x = Dialing command
Default:
None
Description:
Stores dialing command x in memory location y. Dial the
stored number using the command ATDS=y. See also
the #CBSn command. For callback security options, see
Chapter 6.
Command: \An Select Maximum MNP Block Size
Values:
n = 0, 1, 2, or 3
Default:
3
Description: \A0 64-character maximum.
\A1 128-character maximum.
\A2 192-character maximum.
\A3 256-character maximum.
Command: \Bn Transmit Break
Values:
n = 09 in 100 ms units
Default:
3
Description:
In non-error-correction mode only, sends a break signal
of the specified length to a remote modem. Works in
conjunction with the \K command.
Command: \Gn Modem Port Flow Control
Values:
n = 0
Default:
0
Description: \G0
Returns an OK for backward compatibility with some
software.
\G1
Not supportedresponds ERROR.
Command: \Jn
Data Buffer Control
Values:
n = 0
Default:
0
Description: \J0
Enable data bufferserial port speed is independent of
connect speed.
\J1
Disable data bufferserial port speed is forced to the
line speed.