Multi-Tech Systems ISI5634PCI/4/8 User Manual
Page 78

78
ISI5634PCI/4/8 User Guide
Command: Cn
Carrier Control
Values:
n = 1
Default:
1
Description: C0
Transmit carrier always off. (Not supported.)
C1
Normal transmit carrier switching (included for back-
ward compatibility with some software).
Command: Ds
Dial
Values:
s = dial string (phone number and dial modifiers)
Default:
none
Description:
Dial telephone number s, where s may up to 40
characters long and include the 09, *, #, A, B, C, and
D characters, and the L, P, T, V, W, S, comma (,),
semicolon (;), !, @, ^ and $ dial string modifiers.
Dial string modifiers:
L Redial last number. (Must be placed immediately
after ATD.)
P Pulse-dial following numbers in command.
T Tone-dial following numbers in command (default).
W Wait for a new dial tone before continuing to dial.
(X2, X4, X5, X6, or X7 must be selected.)
,
Pause during dialing for time set in register S8.
;
Return to command mode after dialing. (Place at end
of dial string.)
!
Hook flash. Causes the modem to go on-hook for one-
half second, then off-hook again.
@ Wait for quiet answer. Causes modem to wait for a
ringback, then 5 seconds of silence, before process-
ing next part of command. If silence is not detected,
the modem returns a NO ANSWER code.
^ Disable data calling tone transmission.
$ Detect AT&T call card bong tone. The character
should follow the phone number and precede the
users call card number:
ATDT1028806127853500$123456789