Next sweep, Attenuation, Attenuation graph – Microtest TSB-67 - 568A Annex E User Manual

Page 43: Attenuation limits

background image

Page 43

Note: See Chapter 3: Autotest for more information on NEXT testing.

NEXT Sweep

To display this screen, press the

Measure Cable Performance

key, then select

NEXT

, then press

Sweep (F2).

This screen allows you to select the sweep range and step method for NEXT tests.

If your Scanner has an alphanumeric overlay on the keypad, use the keypad to enter the new sweep
limits. If your Scanner does not have an alphanumeric overlay, press

Edit (F2)

to display the edit

screen.

Press the

ESCAPE

key to return to the

NEXT

results screen.

Attenuation

To display the

ATTENUATION

screen, press the

Measure Cable Performance

key, then select

Attenuation

.

Press

Graph (F1)

to enter graphing mode.

Press

Sweep (F2)

to display the Attenuation results at different frequencies.

Press

Pair (F3)

to toggle through the available pair combinations.

Press the

ESCAPE

key to return to the

MEASURE CABLE PERFORMANCE

screen.

Attenuation Graph

To display this screen, press the

Measure Cable Performance

key, then select

Attenuation

, then

press

Graph (F1).

This screen displays the Attenuation graph for the indicated pair combination.

Press

Zoom (F1)

to magnify the area of the graph around the cursor. The Zoom key can display

1x, 2x, 5x or 10x magnification.

Press

Print (F2)

to print the Attenuation graph.

Press

Test (F3)

to rerun the Attenuation test and display new data.

Press the

ESCAPE

key to return to the Attenuation screen.

Note: See Chapter 4: Editing, Printing & Updating for more information on printing.

Attenuation Limits

To display this screen, press the

Measure Cable Performance

key, then select

Attenuation

, then

press

Sweep (F2).

This screen allows you to change the Attenuation Sweep range and step criteria.

Press the

Ñ

or

Ò

key to highlight the field to change. Use the Scanner keypad to enter the range

values, or press

Change (F2)

to toggle through the Criteria values.

When entering range values, press

Del (F2)

to delete the number at the cursor. On the

PentaScanner+,

there is also a numeric mode, indicated by

NUM (F3).