Capacitance test results, Saving autotest results – Microtest TSB-67 - 568A Annex E User Manual
Page 29

Page 29
If your Scanner has an alphanumeric overlay on the keypad, use the keypad to enter the limits. If
your Scanner does not have an alphanumeric overlay, press
Edit (F2)
to display the edit screen.
After editing, press
Save (F1)
to store the new Capacitance limits and exit or press the
ESCAPE
key to exit without saving.
Capacitance Test Results
To display the
CAPACITANCE
screen, press
View (F1)
from the
AUTOTEST RESULTS
screen,
then press the
Ò
key until the
CAPACITANCE
screen is displayed.
At the upper left of the screen, the pair corresponding to the displayed result is shown. The
capacitance, in picofarads (pF), is shown to the right of the pair. The PASS/FAIL bar across the
screen compares the measured Capacitance value to the Capacitance limit value. Below the
PASS/FAIL bar, the Capacitance limit value is displayed. The Autotest name is displayed after
Spec:
at the lower left of the screen.
Press
Table (F1)
to display the Capacitance test results for all pairs or press
Pair (F3)
to toggle
through the Capacitance test results for each pair.
Press the
Ñ
or
Ò
arrow key to display the previous or next test results screen.
Press the
ESCAPE
key to return to the
AUTOTEST RESULTS
screen.
Note: For diagnostic purposes, you can run Capacitance continuously by pressing the Measure
Cable Performance key and selecting Capacitance.
Saving Autotest Results
This screen lets you store Autotest results in the Scanner’s memory. To display the
SAVE TEST
screen, press
Save (F2)
from the
AUTOTEST RESULTS
screen. Press the
Ñ
or
Ò
arrow key
to highlight the field to update.
If your Scanner has an alphanumeric overlay on the keypad, use the keypad to enter field values.
When editing the Circuit ID, press F3 to change editing modes (
CAPS, caps, NUM
or
Inc
).
Increment (
Inc
) mode automatically increments the last character position, and lets you manually
increment or decrement any character using the
Ñ
or
Ò
arrow key.
To start the Automatic Increment function:
1.
Run the initial Autotest.
2.
Enter the initial Circuit ID.
3.
Set F3 to Inc mode.
4.
Press F1 to save the Autotest.
After performing the next Autotest, enter the
SAVE TEST
screen. The Scanner will automatically
increment the last field in the Circuit ID. Press
F1
to save the Autotest.
When you enter the initial Circuit ID, you can divide the fields by using non-alphanumeric
characters. The non-alphanumeric characters are considered field separators. For example, the
Circuit ID BLDG-001 is divided into two fields by the ‘-’ character. In Automatic Increment
mode, the Scanner will automatically increment the last field, “001”, from “001” to “999” and
then roll back to “000”. Both alphabetic and numeric characters (A-Z, a-z, 0-9) will be
incremented if the circuit ID contains both types of characters.