Snmp read/write settings, Snmp read/write settings -16 – Moxa Technologies Moxa EtherDevice Switch EDS-405A User Manual
Page 31

EDS-408A/405A Series User’s Manual
Featured Functions
3-16
SNMP Read/Write Settings
SNMP Versions
Setting
Description
Factory Default
V1, V2c, V3
Select SNMP protocol versions V1, V2c, 
V3 to manage the switch 
V1, V2c
Select SNMP protocol versions V1, V2c to 
manage the switch 
V3 only
Select only SNMP protocol version V3 to 
manage the switch 
V1, V2c
V1, V2c Read Community
Setting
Description
Factory Default
V1, V2c Read 
Community 
Use a community string match for 
authentication. This means that the SNMP 
agent accesses all objects with read-only 
permissions using the community string 
public. 
public 
Maximum 30 characters
V1, V2c Write/Read Community
Setting
Description
Factory Default
V1, V2c 
Read/Write 
Community 
Uses a community string match for 
authentication, which means that SNMP 
servers access all objects with read/write 
permissions using the community string 
private. 
private 
Maximum 30 characters 
For SNMP V3, there are two levels of privilege for different accounts to access the EDS. Admin 
privilege allows access, and authorization to read and write the MIB file. User privilege only 
allows reading the MIB file, but does not authorize writing. 
 
 
 
 
 
 