Read all instructions completely and thoroughly before attempting installation. Failure
to do so could result in serious injury, property damage or loss of life. Operation of
improperly installed and maintained venting system could result in serious injury,
property damage or loss of life.

W

ARNING

Failure to follow these instructions will
void the warranty.

NOTICE

INSTALLATION PRECAUTIONS

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system
for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.
Only a qualified installer/service person should install venting system. The installer must follow these safety rules:
• Wear gloves and safety glasses for protection.
• Use extreme caution when using ladders or when on rooftops.
• Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your venting system:
• Installation of any damaged venting component.
• Unauthorized modification of the venting system.
• Installation of any component part not manufactured or approved by MHS.
• Installation other than permitted by these instructions.

FINISHING MATERIAL

NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to fi nal
fi nishing to avoid costly reconstruction.

INSTALLATION INFORMATION

Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used
to cover the black painted face of the appliance. It is permissible to bring combustible wall board to the top and side
edges of the black painted face. A 300°F minimum adhesive may be used to attach facing materials to the black surface.
If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General
Electric RTV103 or equivalent) must be used.

VENT INSTALLATION

This fi replace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.

W

ARNING