beautypg.com

Warning clearances, Clearances to combustibles mantel clearances – Monessen Hearth Direct Vent BLDV400 User Manual

Page 10

background image

10

74D0009

13" M

IN.

6" MIN.

FROM OP

ENIN

G

71" MINIMUM

CIELING

MANTEL S

HELF

:

0-12”

MAX DE

PTH

Follow these instructions carefully to ensure safe installation. Failure to follow
in struc tions exactly can create a fi re hazard.

The appliance cannot be installed on a carpet, tile or other combustible material other
than wood fl ooring. If installed on carpet or vinyl fl ooring, the appliance shall be installed
on a metal, wood or noncombustible material panel ex tend ing full width and depth of
the appliance.

W

ARNING

CLEARANCES

CLEARANCES TO COMBUSTIBLES

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than

3

/

4

" from the facing. If it does,

it is considered a mantel and must meet the mantel requirements listed in this manual.

Figure 5 - Clearances from the mantel,

ceiling, and side wall.

Figure 5a - Mantel clearances.

FIREPLACE

WALL

COMBUSTIBLE

MATERIAL

AREA

6"

5"

3"

2.5"

4.5"

45°

3.5"

3.5"

1"

1.5"

1.5"

All mantel shelves, regardless of depth, should be a
minimum of 13" from top opening of fireplace. Mantel
shelf shall not exceed 12" max. depth at 13" minimum
height from opening.

NOTE

: