Adjusting the coin mechanism timer – Manitowoc Ice Q290 User Manual
Page 11
1-5
Section 1
General Information
Adjusting the Coin Mechanism Timer
1. Remove the control box cover. On the inside of
the control box there is a white instruction label
which shows how to set intervals for coin
mechanism dispense times.
2. Inside the control box, the coin mechanism timer
is to the left. The ice agitation timer is to the
right.
3. With a small Phillips head screwdriver, adjust the
coin mechanism timer. For timer adjustment
reference information, see below or refer to the
white instruction label inside the control box
cover.
4. The timer is factory set at the midpoint (as shown
above) for 60 seconds of dispense time.
The adjustment pot can be set (counterclockwise)
for as low as 12 seconds of dispense time.
The adjustment pot can be set (clockwise) for as
high as 120 seconds of dispense time.
COIN MECHANISM
TIMER